Spark detector for Alpha particles

Spark detector

This is a spark detector for alpha particles from an Americium sample. It runs on 6 kV via a 400 k ohm resistor and a 100 pF capacitor and has about 0.2 inches between wires and is about 0.2 inches deep.
“Continue Reading” for animation of the sparks more details and links…

Spark detector

The wires are not ideal and have imperfections so don’t have a good distribution of sparks. The left half of the wires are from single strands of tinned copper wire from a small insulated connecting wire from a microwave oven. The right side is slightly thicker stainless steel wire.  Tungsten wire would be preferable but the only size I have is a ridiculous 0.0015 inch.
The wires need to be of uniform height and tension so they don’t sag. Also being individually replaceable would be helpful if they are bumped or broken.

I am looking for a better version later with on board power supply. The voltage needs to recover rapidly so the next spark can happen but not accumulate with a progressively rising voltage so that it begins to spark by itself. A voltage multiplier might not be best and the supply should be regulated to allow fine adjustment.

Related pages

Geiger counter reading 80180 CPM with Americium sample from alpha radiation   Alpha Radiation Geiger counter readings
Spinthariscope under UV   Spinthariscope Visible alpha radiation

Try something else

Spooky spider eyes   Spiders Eyes  remarkable spider eye reflections

External links

 Alpha spark detector video

Photo Date:  May 10, 2012

Leave a Reply

Your email address will not be published. Required fields are marked *